How-to guide·Using BIM.worksRequires PREDEFINED_QUERIESRequires NEW_IDS

Run an IDS check

Add an IDS to the Actions tree by dropping the file or with Add new → IDS Check, run it on the loaded models and read the result tree.

An IDS (Information Delivery Specification) is a buildingSMART XML file that says which objects a model must contain and what data they must carry. In BIM.works an IDS is an Action in the Actions tree: it is stored once and runs against whatever models are loaded. The same check is available from the API (Run an IDS check via the API).

Before you start#

You need the PREDEFINED_QUERIES and NEW_IDS feature flags, an .ids file (IDS 1.0), and the models to check ticked in the Models tree.

Steps#

  1. Open the Actions tab and navigate to the folder the check should live in. The Examples folder is read-only; use your own folder.
  2. Add the IDS in one of two ways:
    • Drop the .ids file on the folder. The action takes its name from the title in the IDS info block. A file that is not well-formed XML is refused with the parser's message.
    • Add new → IDS Check opens the IDS editor. Give it a name and a description and paste the XML, or start from Start with example IDS and edit it. Format (Ctrl+Shift+F) tidies the XML and Download IDS saves it back to a file. Save closes the editor.
  3. Run it. The check runs on the loaded models as soon as the action is shown, and again whenever the set of loaded models changes. The action's row shows the counts: errors in red, warnings in orange, successes in green, information in blue.
  4. Read the results. Expand the action: the first level is one node per specification in the IDS, the second level lists the objects each specification applied to, with the result per requirement on the object. Clicking an object selects it in the viewers.
  5. Use the action's menu (the … button) for the overview: Show only errors or Show only successes colours those objects red or green, hides everything else and fits the view to them; Show all results colours both. JSON View shows the raw result; Report opens the charts (CHECK_CHARTS); Download as BCF exports the failed objects as BCF issues with viewpoints.
Tip

An .ids file dropped on the Models tree is not a model: BIM.works refuses it and points at the Actions tab.

Check#

Load a model that should fail one requirement and expand the action: the specification node lists the object with an error, and Show only errors isolates it in red in the 3D viewer.