Errors
A failed call answers with an HTTP status and an ErrorResponse body that names the error code and its enumeration.
A failed call has an HTTP status and a JSON api/schemas#ErrorResponse body:
JSON#
{"code": 6, "type": "UNKNOWN_TYPE", "domain": "BimWorksQueryError", "domain_full": "nl.bimbase.bimworks.common.actions.BimWorksQueryError", "message": "Unknown IFC type IFCWAL"}type and domain name the constant and its enumeration on the error codes page, code is the constant's number within that enumeration, and message is for people.
| Status | When |
|---|---|
400 |
Invalid input: a missing or invalid argument, an invalid query, identifier or path, a state conflict the request caused (a node name that already exists), or an uploaded file that cannot be read (INVALID_INPUT_FILE, NO_CONVERTIBLE_CONTENT, a StepParserErrorCode); uploading the same file again fails the same way. |
401 |
The bearer token is missing, malformed, expired or otherwise invalid, or the login credentials are wrong. |
403 |
Authenticated but not allowed: no read or write right on the node, a token without the operation's scope or locked to another IP, or a required user feature missing. |
404 |
The node, version, model file or upload does not exist. |
409 |
The request conflicts with the current state: a transaction against a version that is no longer the head of its node. |
413 |
The request body is larger than the instance accepts (PAYLOAD_TOO_LARGE); the limit of a standard installation is 1 GB. |
429 |
Too many requests from this client in a short time (TOO_MANY_REQUESTS), on an installation that limits the request rate. |
500 |
An unexpected server-side error. |
502 |
An upstream answer was unusable: AddModelWithUrl could not reach the host of the URL (UPLOAD_URL_NO_ROUTE_TO_HOST), or the language model of TextToAction gave no usable Action (OPEN_AI_IGNORED, AI_RETURNED_INVALID_ACTION). |
503 |
The instance is restarting, stopped or down for maintenance (SERVICE_UNAVAILABLE, MAINTENANCE), or a server of the cluster that must store a file is down (REPLICATION_FAILED). |
504 |
The reverse proxy stopped waiting for the answer (REQUEST_TIMED_OUT; after ten minutes on a standard installation). The request may still complete, so look for its result before you send it again. |
The reverse proxy in front of the server answers 413, 429, 503 and 504 itself, with the same body (domain DefaultErrorCode) and an X-BIMworks-Proxy-Error header; on 429 and 503 the Retry-After header gives the seconds to wait before trying again.
See also
Error codes · reference