---
title: How calculated quantities are measured
summary: An illustrated guide to all 44 calculated quantities, from dimensions and primary faces to solid volumes, stair measurements, opening deductions and Advanced mesh measurements.
order: 85
terms: [calculated-value, quantity, quantity-set]
see-also: [reference/bql/calculated-values, reference/bql/quantities, tutorials/bql/calculated-values, demos/quantity-takeoff]
---

# How calculated quantities are measured

BIM.works derives [[term:calculated-value|calculated values]] from an object's geometry when the model is processed. These [[term:quantity|quantities]] describe the represented shape, including its placement, parts and openings. The [[term:quantity-set|quantity sets]] supplied by the authoring tool remain separate, so you can compare the two.

The object panel shows them under **Calculated → Quantities**. Hover a row for its definition, accuracy information and documentation icon and, where a measurement figure is available, to see the geometry measured in the 3D viewer. An **≈** marks a measurement whose maximum error is unknown or exceeds the [accepted accuracy limits](#accuracy). Unsupported or invalid measurements read **Unavailable**; they do not become zero.

Every key in the tables below belongs to `calculated.quantity.<key>` in BQL. Lengths have length units, areas have squared units, volumes have cubic units, and counts are unitless counts. Use `UNIT m`, `UNIT m2` or `UNIT m3` to request a particular display unit.

## Reading the pictograms {#pictograms}

**Blue shading or a blue line** identifies the measured region. **Double-ended arrows** identify a distance. **Grey dashed outlines** identify an enclosing box or another reference. **Hatching** identifies an opening or a region counted more than once. The illustrations are schematic: their labels, arrows and boundaries carry the meaning as well as their colours.

## Horizontal dimensions and vertical height {#dimensions}

Plan dimensions use a horizontal enclosing rectangle fitted to the projected object. They follow that rectangle's directions rather than global X and Y. Height always follows the model's vertical direction. A railing's defined route is a separate case: its length follows the bends in that route.

![Top view with fitted length and width arrows, elevation with a vertical height arrow, and a bent railing whose route length differs from its straight enclosing span.](calculated-quantities/dimensions.svg)

| Key | Panel label | What is measured |
|---|---|---|
| `length` | Length; Route length on a railing with a defined route | Overall horizontal extent in the selected length direction. A defined railing route instead gives its horizontal path length, including bends. |
| `width` | Width | Overall horizontal extent perpendicular to length. For a railing with a route, the maximum depth across that local route. |
| `height` | Height | Highest placed point minus lowest placed point. This includes the elevation change of a sloping object. |
| `footprintLength` | Footprint length | Longer extent of the fitted horizontal enclosing rectangle. |
| `footprintWidth` | Footprint width | Shorter perpendicular extent of that rectangle. |
| `footprintArea` | Footprint area; Box footprint area for generic objects | Area of the union of the vertical projections for supported object types. Generic objects use the whole enclosing rectangle instead. |

`footprintLength × footprintWidth` is the rectangle's area. It need not equal the actual footprint area. AABB width and depth use global X and Y; OBB extents use the oriented box's own axes. Neither is a universal substitute for these plan dimensions.

## Thickness and its range {#thickness}

Thickness goes through the object under its category's convention. For walls this is a horizontal separation across the wall; for slabs it is normal to the principal surface. On a sloping slab, normal thickness differs from vertical height. On a curved wall, local thickness differs from the width of its entire plan envelope.

![A straight wall with one depth, a tapered wall with different minimum and maximum thickness arrows, and a sloping slab with a short normal thickness arrow and a separate full vertical height arrow.](calculated-quantities/thickness.svg)

| Key | Panel label | What is measured |
|---|---|---|
| `thickness` | Thickness | Separation through the primary opposing surfaces. A single value is unavailable when the supported measurement finds varying thickness. |
| `minThickness` | Minimum thickness | Smallest supported separation across paired gross wall sides or opposing slab surfaces. Openings do not introduce a false zero thickness. |
| `maxThickness` | Maximum thickness | Largest supported separation across those paired sides or surfaces. |

The panel collapses explicit copies of the same measurement. It retains separately measured extrema even when their numeric values match.

## A footprint counts overlapping projections once {#footprint}

For supported types, the footprint is the union of everything projected vertically onto the horizontal plane. A hole remains only where no part of the object projects into it. A wall above a window still projects over the window, while a through-hole in a slab can remain a hole in its footprint.

![Two elevated two-by-two metre plates overlap by two square metres in plan. The projected union is six square metres, while summing their downward projections gives eight square metres.](calculated-quantities/footprint.svg)

In the pictured example, both plates are part of **one object**. Their footprint is **6 m²** and their summed downward projected area is **8 m²**. `floorArea` uses the latter calculation; it is not another name for `footprintArea`. When summing quantities across separate objects, BQL adds their individual values and does not union their projections across objects.

## Gross and net primary surfaces {#surfaces}

A primary surface is one logical side of an object, potentially made from many triangles or curved patches. For a wall, door or window, the calculator selects the side with the greatest reconstructed gross area. For a slab it selects the principal top face. Gross and net refer to that **same side**.

![A four-by-three metre wall face has twelve square metres gross surface. Removing a one-by-two metre opening leaves ten square metres net surface. Edge faces and opening reveals are outside both shaded primary faces.](calculated-quantities/surfaces.svg)

| Key | Panel label | What is measured |
|---|---|---|
| `grossSurface` | Gross surface; Box surface area for generic objects | Primary-face area with opening regions restored inside the real outer boundary. Generic objects instead use all six faces of their enclosing box. |
| `netSurface` | Net surface | Remaining area of the same primary face after empty openings are removed. Edge faces, ends and reveals are excluded. |

Surface area follows the actual slope or the developed curved side. It is not necessarily `length × height`. For doors and windows, frame, leaf, panels and glazing count as occupied material; transparent glazing is not an empty aperture. The represented state matters: an open leaf can change the footprint and assembly depth.

## Gross box volume and net solid volume {#volumes}

Gross volume has two conventions. Walls, members, doors, windows and generic objects use an enclosing **box**, which includes empty space inside that box. A slab uses its **uncut solid**, preserving its actual outer outline. Net volume measures the effective solid after voids and overlapping material are accounted for.

![An L-shaped member occupies only part of its enclosing box. A slab's gross and net volumes retain the same nonrectangular outer outline, with the opening filled for gross volume and removed for net volume.](calculated-quantities/volumes.svg)

| Key | Panel label | What is measured |
|---|---|---|
| `grossVolume` | Gross box volume, Gross volume, or Box volume | Member-aligned enclosing-box volume for members; horizontal enclosing-box volume for walls, doors/windows and generic objects; uncut-solid volume for slabs. |
| `netVolume` | Net volume | Effective solid volume, excluding voids and counting overlapping material once. It requires a supported solid measurement. On an opening with one measured host, this is a copy of the removed opening volume. |

A circular member's enclosing box contains empty corners, so its gross box volume exceeds its solid volume even with no openings. Gross and net can also happen to match on a rectangular solid; their definitions remain different. The older `volume` value is a raw mesh measurement, described under [Advanced](#advanced).

## Developed wall lengths and the centreline {#wall-lengths}

Curved and bent wall lengths follow their longitudinal boundaries. They differ from the straight overall plan extent. In the quarter-circle example below, the inner radius is 2 m and the outer radius is 2.2 m: the three developed lengths are π m, 1.05π m and 1.1π m.

![A quarter-circle wall shows its shorter inner boundary, dashed middle axis and longer outer boundary. Each length follows its curve rather than the straight plan span.](calculated-quantities/wall-lengths.svg)

| Key | Panel label | What is measured |
|---|---|---|
| `shortestLength` | Shortest length | Shorter developed plan length of the paired longitudinal wall boundaries between matching end stations, measured without opening cut-outs. |
| `axisLength` | Length at axis for walls; Length along axis for members and flow objects | Wall reference centreline projected horizontally, or an estimated midline where supported. For a member or flow object, the three-dimensional longitudinal centreline or route instead. |
| `longestLength` | Longest length | Longer developed plan length of the paired longitudinal wall boundaries between matching end stations. |

The wall axis is horizontal in this measurement convention. A sloping beam or pipe's axis is three-dimensional. A vertical column therefore has a nonzero axis length even though its plan extent along the axis is zero.

## Member sections and surfaces {#members}

Section width and height lie in a plane perpendicular to the longitudinal axis. Section height is therefore a different direction from vertical object height. A verified circular section also has an outside diameter.

![An inclined member has a three-dimensional longitudinal axis and a perpendicular rectangular section with width and height arrows. A circular section has a diameter arrow. Separate member views shade the lateral surface and the two terminal ends.](calculated-quantities/members.svg)

| Key | Panel label | What is measured |
|---|---|---|
| `sectionWidth` | Section width | Width extent perpendicular to the member or flow axis, from the supported profile or an inferred section frame. |
| `sectionHeight` | Section height | Height extent in that perpendicular section plane, independent of vertical height. |
| `diameter` | Diameter | Outside diameter of a verified circular section. A rectangular or unsupported varying section has no single circular diameter. |
| `outlineSurface` | Outline surface | Lateral member boundary, excluding terminal ends. Includes exposed inner surfaces of hollow sections and cut-out reveals. |
| `endsSurface` | Surface of ends | Combined areas of the longitudinal terminal end faces, excluding holes in the section. |

For a straight, square-ended prismatic member, its aligned box reduces to `axisLength × sectionWidth × sectionHeight`. This is not a general box-volume formula for curved or mitred members. Flow objects need a supported route to report route-based measurements; an overall box does not establish a pipe or duct centreline.

## Three slab perimeters {#perimeters}

The outer perimeter excludes inner hole boundaries. Opening perimeter counts the inner boundaries of projected through-holes. Total perimeter includes all boundaries of the final projected footprint.

![A four-by-two metre slab with a one-by-one metre internal hole has twelve metres of outer boundary, four metres of opening boundary and sixteen metres of total boundary.](calculated-quantities/perimeters.svg)

| Key | Panel label | What is measured |
|---|---|---|
| `outerPerimeter` | Outer perimeter | Outer boundary of the slab's gross horizontal projection, with internal holes excluded. |
| `openingPerimeter` | Opening perimeter | Inner hole boundaries of the final horizontal projection. |
| `totalPerimeter` | Total perimeter | Outer and inner boundaries of the final horizontal projection. |

For the internal hole pictured above, total is outer plus opening perimeter. Do not apply that identity to every slab: an opening that cuts through an outside edge changes the final outer boundary, while `outerPerimeter` comes from the gross projection. The older mesh `perimeter` has another definition.

## Stairs and walking geometry {#stairs}

Stair measurements follow walking faces and risers rather than the whole bounding rectangle. A landing is not an extra tread. The pictured flight has five risers and four treads before the upper landing.

![Stair side elevation distinguishes five risers, four treads and an excluded upper landing. Arrows show total rise, one riser height, one tread depth and the full run. A plan view shows run width across the flight.](calculated-quantities/stairs.svg)

| Key | Panel label | What is measured |
|---|---|---|
| `totalRise` | Total rise | Difference between the lowest and highest connected walking levels. If walking geometry cannot be established, the available fallback is whole-object vertical extent. |
| `riserCount` | Number of risers | Number of identified vertical steps across the measured flights. |
| `treadCount` | Number of treads | Number of identified walking treads across the flights, excluding landings. |
| `riserHeight` | Riser height | One riser-height value when the identified risers are uniform within the calculator's tolerance. |
| `minRiserHeight` | Minimum riser height | Smallest identified vertical riser height. |
| `maxRiserHeight` | Maximum riser height | Largest identified vertical riser height. |
| `runWidth` | Run width | Clear side-to-side width of a supported single flight, measured across its walking direction. |
| `runDepth` | Run depth | Horizontal extent of that flight's walking faces along the run direction. |
| `treadDepth` | Tread depth | One tread's horizontal depth, where supported straight rectangular treads have a uniform depth. |

Overall object height can include material below the first walking level or other parts outside the walking rise. A multi-flight stair can have aggregate rise and counts while flight-specific widths and depths remain in its calculation details. Ambiguous steps or unsupported walking directions leave the affected measurements unavailable.

## Openings are clipped to their host {#openings}

An opening's cutting shape can extend well beyond a wall or slab. Its public quantities describe the **removed host material**, rather than that oversized cutting shape. In the example, a 1 × 2 m opening through a 0.2 m wall removes 0.4 m³.

![The opening face measures one by two metres. In side section an oversized dashed cutter extends beyond the wall, while the highlighted host intersection is only 0.2 metres deep. The removed volume is 0.4 cubic metres.](calculated-quantities/openings.svg)

| Key | Panel label | What is measured |
|---|---|---|
| `openingArea` | Opening area | Opening area on the selected host primary face, clipped to that face's boundary. |
| `openingDepth` | Opening depth | Penetration through the host, measured on the clipped intersection. Supported curved-wall cases may use an estimated effective depth. |
| `openingVolume` | Opening volume | Volume of the opening's intersection with the host's uncut solid. |

The opening's length, width, height and footprint describe the same clipped intersection. With one measured host, `thickness` copies opening depth and `netVolume` copies opening volume, so the panel shows each measurement once. Multiple hosts retain separate host records; ambiguous scalar measurements are unavailable. A door or window filling the opening does not put wall material back into the wall.

## Floor area stays prominent for spaces {#spaces}

For a space, **Floor area** (`floorArea`) remains in the main quantities group. Its calculation sums downward-facing projected mesh areas. A simple room with one bottom surface therefore yields that floor's plan area; overlapping downward-facing surfaces can contribute more than once.

![An L-shaped space has six square metres of projected floor area. Its enclosing rectangle covers eight square metres, including the missing corner, so box footprint area must not replace floor area.](calculated-quantities/spaces.svg)

Spaces currently use the generic enclosing-box strategy for the newer footprint and gross-box quantities. Their **Box footprint area** can therefore exceed their floor area. The same generic strategy is used for types without dedicated measurement rules, such as furniture and proxies. On those objects, **Box surface area** means all six box faces and **Box volume** includes the empty space inside the box. No net material quantity is inferred from that box.

## Advanced mesh measurements {#advanced}

The older mesh measurements remain under **Quantities → Advanced**, with `floorArea` kept prominent for spaces. These values measure the stored triangles. Directional measurements use the mesh-local frame, so rotating a placed object away from that frame's up direction can change what a world-horizontal projection would mean.

![All triangles contribute to total mesh surface area. Front and back identify a mesh-local opposing pair. A sloping two-by-one metre patch has about 2.83 square metres of face area but only two square metres of upward projected area.](calculated-quantities/mesh.svg)

| Key | Panel label | What is measured |
|---|---|---|
| `volume` | Mesh volume | Absolute signed volume calculated from the stored triangles. Its presence alone does not establish a valid closed solid. It can differ from the validated, union-aware or definition-based `netVolume`. |
| `area` | Total mesh surface area | Sum of every stored triangle's actual area, including faces, edges, ends and reveals. It is not the area of a single primary side. |
| `floorArea` | Downward projected area; Floor area for spaces | Sum of downward-facing triangle areas projected onto the mesh-local horizontal plane, with multiplicity where projections overlap. |
| `perimeter` | Mesh patch perimeter | Sum of projected boundary lengths of downward-facing triangle patches. Includes holes and counts stacked patches separately; unavailable when the mesh edge calculation is skipped. |
| `frontArea` | Front mesh face area | Actual area of faces classified towards the positive axis of the dominant mesh-local opposing horizontal pair. Front does not identify the building's exterior. |
| `backArea` | Back mesh face area | Actual area of faces classified towards the opposite direction of that pair. Back does not identify the building's interior. |
| `topArea` | Upward projected area | Sum of upward-facing triangle areas projected onto the mesh-local horizontal plane. This is projected area, not sloped face area; overlapping projections can count more than once. |

The same sloping triangle can contribute to more than one directional face classification. Adding directional face areas is therefore not a way to recover total mesh surface area.

![Two two-by-two metre patches at different heights each contribute eight metres of downward-patch boundary. Their mesh patch perimeter is sixteen metres, while their united three-by-two metre plan footprint has ten metres of outside boundary.](calculated-quantities/mesh-perimeter.svg)

Here the mesh patch perimeter is **16 m** and the united plan outline is **10 m**. Equal perimeter values on a simple box do not make the two measurement methods interchangeable.

## Space boundary area {#boundaries}

Space boundaries are separate entities describing the relation between a space and its surroundings. Their area has its own scope; it is not the entire wall's primary-face area and is not the space's floor area.

![One wall borders two spaces. Only the highlighted portion belonging to space A contributes to that space boundary's area; the neighbouring space's portion and the wall's whole face are separate scopes.](calculated-quantities/boundaries.svg)

| Key | Panel label | What is measured |
|---|---|---|
| `boundaryArea` | Boundary area | Area of the generated geometry for one space-boundary entity. It remains in the main quantities group. |

## Which quantities an object has {#availability}

| Object category | Main measurement rules |
|---|---|
| Walls and wall-like coverings | Plan extents, wall thickness, primary surfaces and box/solid volumes; paired boundary lengths and thickness ranges where supported. |
| Slabs and horizontal coverings | Plan footprint, normal thickness, top primary surface, three perimeters and uncut/net solid volumes. |
| Columns, beams and members | Longitudinal axis, perpendicular section, lateral/end surfaces, member-aligned box and effective solid volume. |
| Flow objects | Supported three-dimensional route and section dimensions, plus footprint and available effective solid measurements. |
| Railings | Horizontal route where available, depth across it, vertical extent and footprint. |
| Doors and windows | Represented assembly extents, primary surfaces, enclosing box and available effective solid volume. |
| Stairs and flights | Walking levels, risers, treads and supported single-flight run dimensions, plus overall extents and footprint. |
| Openings | Measurements clipped to each host. |
| Other types, including spaces, furniture and proxies | Horizontal enclosing-box estimates for the newer box quantities; older mesh measurements where geometry exists. |

Supported IFC definitions can give more accurate measurements than tessellated triangles. Otherwise BIM.works uses mesh geometry or a documented estimate. Calculation details identify the basis, source and availability. Some assemblies obtain measurements from their parts even without their own geometry.

Only quantities that reuse the same measurement are collapsed in the panel. Matching numbers do not establish equivalence: gross/net areas, extrema, axis/side lengths and separately calculated section bounds keep their own meanings. Every BQL key in this page remains available, including names whose repeated panel rows are collapsed. Advanced is a panel group, not a query-path segment.

## Accuracy and the approximation marker {#accuracy}

A quantity shows **≈** when its calculation approximates the represented IFC geometry. The measurement record names the reason as `approximation`:

| `approximation` | The value |
|---|---|
| `curvedGeometry` | Is measured on the triangles of curved surfaces: a circular, elliptical, rounded or filleted profile, a profile or route with arcs or splines, a revolved, swept-disk or other curved solid, or a curved opening in the object. |
| `inferredReference` | Depends on a reference the model does not define: a member's axis, section, box and end faces when no extrusion defines its axis, a stair run along an inferred walking line, or a wall's axis length taken from the midline between its sides. |
| `sampled` | Is measured on a raster of the footprint, used when its exact union would be too large. |
| `approximatedDefinition` | Is read from the IFC definition, but that definition's profile or curve was evaluated approximately. |
| `unclassifiedGeometry` | Is measured on a representation type that is not known to triangulate exactly. |
| `errorBoundExceeded` | Has a proven maximum error, but over the limits below. |
| `unrecorded` | Was stored by an older calculation that did not record this. Regenerate the quantities. |

Every other value is calculated without approximation. Planar geometry is its own triangulation, and the algorithms that measure it are exact apart from floating-point rounding: the divergence volume, polygon unions and the rotating calipers that find extents. Profile areas, arc lengths and extrusion volumes read from the definition are evaluated in closed form. Curved surfaces mark every length, area and volume measured on the object's triangles, including one that a straight edge decides, such as a cylinder's height. Counts are never approximated, and a value read in closed form from a curved definition is not either.

A certificate can also remove the marker: a value whose own maximum error is proven to meet the limits below shows no **≈**, even when its calculation approximates. “Exact” and “within the limits” refer to the represented IFC geometry; neither certifies the constructed building.

| Measurement type | Absolute error must be below |
|---|---|
| Overall length, width, height, footprint dimensions, developed wall lengths, axis or route length, perimeters, total rise and flight run dimensions | **1 mm** |
| Thickness and its range, section dimensions, diameter, individual riser heights, tread depth and opening depth | **0.1 mm** |
| Every area, including primary faces, footprints, opening areas and Advanced mesh areas | **1 cm²** (`0.0001 m²`) |
| Every volume, including solid, box, opening and Advanced mesh volumes | **1 cm³** (`0.000001 m³`) |
| Riser and tread counts | **Zero error**, with the counted elements established |

Dimensional measurements must also have error below **0.1% of the smallest possible true magnitude** in their certified interval. Both limits apply, before display rounding and independently of the chosen display unit. A proven zero is exact; a small uncertain value is not converted into an exact zero. A bound exactly at a cutoff retains **≈**.

The tooltip says which applies: calculated without approximation, exact or proven within the limits, approximated and why, or a known bound that fails these limits. The bound is specific to the quantity: an extrusion's defined length or thickness can qualify even when its rounded profile area does not; a defined pipe diameter can qualify even when its sampled route length does not. Supported certificates use outward-rounded intervals from the defining dimensions and compare those intervals with the actual returned value, accounting for its numerical deviation.

Certificates currently cover supported rectangular, rounded rectangular, circular and sharp I profiles under supported rigid placements and uniform mappings, independent extrusion dimensions, explicit swept-disk diameters, and supported simple axis curves. A value outside these cases has no certificate: its `quality` is `unboundedEstimate`, and it shows **≈** only when its calculation approximates. Openings and flights carry their marker per numeric field; their record's summary status does not describe every field.

Advanced mesh measurements and generated space boundaries follow the same policy. Their values still describe the documented triangles, projection multiplicity or boundary scope; a value stored without a record of its approximation is never shown as exact. The absence of **≈** never changes a mesh measurement into a different solid, surface or floor-area convention.

Request one measurement with `GET calculated.quantity.<key>.measurement`, or all records with `GET calculated.details`. Full quantity requests and `GET calculated.*` include the record beside each numeric pack as `measurement`; broad requests retain all records under `calculated.details.measurements`, including unavailable quantities without a numeric pack. For BQL filters and BVL coloring, use `calculated.quantity.<key>.quality`. Each record identifies `quality` as `analytic`, `bounded`, `unboundedEstimate` or `unavailable`, separately from `accuracy.qualified`. An analytic or bounded calculation can still exceed its cutoff. See [[page:reference/bql/calculated-values#measurement|Measurement quality and accuracy]] for the response fields. Accuracy metadata is also under `calculated.details.measurements.<key>.accuracy`. Bounds and cutoffs use SI units; numeric quantity packs retain their original values and query names. Records of models checked in before this policy have no `approximation`: until their quantities are regenerated, their values keep **≈** unless a certificate qualifies them. When adding measurements, accumulate their error bounds: individually accepted values do not automatically establish the accuracy of their total.

## Querying and inspecting a measurement {#queries}

Read the net primary side and material volume of walls:

```bql
GET qid, attribute.Name, calculated.quantity.netSurface UNIT m2, calculated.quantity.netVolume UNIT m3
WHERE type = IFCWALL
```

Read the verification figure for a supported measurement:

```bql
GET qid, calculated.quantity.netSurface, calculated.quantity.netSurface.figure
WHERE type = IFCWALL
```

Find objects without an available net volume before relying on a total:

```bql
GET qid, attribute.Name
WHERE type = IFCWALL AND calculated.quantity.netVolume = null
```

The query path uses singular `quantity`; returned JSON uses `calculated.quantities`. A measurement figure, when provided, uses metres in model coordinates. See [[bql:calculated-values]] for calculated properties, geometry flags, consistency checks and bounding boxes, and [[page:tutorials/bql/calculated-values]] for querying these values step by step.
